MyVallox 99 CFi enthalpy

MyVallox 99 CFi enthalpy

The MyVallox 99 CFi with an enthalpy cell is a low and extremely quiet ventilation unit that fits perfectly above a wash tower, for example. Vallox’s careful air flow optimisation, selected components and well-insulated frame ensure proven quiet operation.

The enthalpy cell recovers both heat and moisture from extract air and transfers them to supply air. This helps maintain pleasant indoor air and prevents excessive dryness, especially during the winter season.

The unit includes integrated carbon dioxide and humidity sensors and versatile control options. Ventilation is boosted automatically according to indoor air quality, and the unit can be controlled with MyVallox Touch or MyVallox Control and through the MyVallox Cloud service. The cloud service enables remote control and automatic updates.

Constant flow fans compensate for pressure differences and keep air flows in balance in windy conditions, tall buildings, during HR cell defrosting and regardless of the heat recovery bypass status. The constant flow feature also compensates for separate extractions and filter contamination. Litre-based air flow adjustment directly from the controller makes installation easier.

Please note! The wall mounting plate must be ordered separately.
Including accessories: MyVallox Control controller, condensing water seal Vallox SilentKlick.

Category:
Suitable for the following applications
Apartment houses icon
Apartment houses
Small houses icon
Small houses
Maximum recommended living area 150 m²
Temperature efficiency of heat recovery (%) 83.8
SEC average climate -40.437 kWh/m²a
Reference airflow rate 0.067 m³/s
Specific power input (SPI) 0.36 W/(m³/h)
Specific Fan Power (SFP) 1.296 kW/(m³/s)
Maximum extract airflow @ 100 Pa 99 l/s
Maximum supply airflow @ 100 Pa 96 l/s
Minimum airflow 10 l/s
Maximum supply airflow EcoDesign 345 m³/h
Duct outlets pcs 4
Duct outlet mm 125 mm
Product depth mm 625
Product width mm 598
Product height mm 442
Product weight 62.3 kg
Package weight 65.1 kg
ETIM EF003701 electrical connection Connection cable with protective earthed plug
Mounting place Wall
Remote monitoring options MyVallox Cloud service, MyVallox Home network, External voltage message 0-10 VDC
Bus control Modbus RTU (standard feature)
Extract air fan power consumption 0.119 kW
Supply air fan power consumption 0.119 kW
Sound power level 43 dB
Cell type Cross-counter flow cell
Cell Enthalpy
HRU cell bypass Automatic heat recovery bypass, partial bypass with cool recovery
Defrosting method Vallox on-demand -defrosting automatics with heat recovery cell bypass
Post-heating Electrical resistor, 900 W
Additional heating Electrical resistor, 900 W
Electrical connection 230 V / 50 Hz / 8,6 A
Encapsulation class IP34
Unit maximum power consumption 2 kW
Coarse filter of supply air ISO Coarse > 75 %
Fine filter of supply air ISO ePM1 50%
Coarse filter of extract air ISO Coarse > 75 %

What is an enthalpy heat recovery cell? How does it differ from an aluminium heat recovery cell?

In terms of operation, the enthalpy heat recovery cell is nearly identical to the aluminium heat recovery cell. The cells are the same size and look similar. The difference is that the cell layers of the enthalpy heat recovery cell are made from film, not aluminium, which is permeable to both heat and moisture.

An enthalpy heat recovery cell prevents excessive dryness of indoor air in winter, it does not freeze as easily as an aluminium heat recovery cell, and it causes less condensation than an aluminium heat recovery cell.

How does the enthalpy heat recovery cell work?

The enthalpy heat recovery cell has a polymer film that it is permeable to moisture. The working principle of the cell is based on water vapour diffusion: Water vapour passes through the film. Moisture is carried from humid air to dry air without mixing the two air flows. Thus, in winter, both heat and moisture is transferred from indoor extract air to cold and dry outdoor air, and vice versa in summer. In summer, the enthalpy heat recovery cell reduces the humidity of supply air when outdoor air is more humid than indoor air, and the air passes through the heat recovery cell. In that case, some of the moisture in outdoor air is transferred to extract air before it reaches the supply air.

Can I replace the aluminium heat recovery cell of my current unit with an enthalpy heat recovery cell?

Yes and no. An enthalpy heat recovery cell is identical in size and shape to an aluminium heat recovery cell, so they are physically interchangeable. However, the unit’s operation is not optimal with an enthalpy heat recovery cell in very cold conditions, as the unit parameters have been designed for an aluminium heat recovery cell. The unit’s factory parameters cannot be changed by the user. After changing the cell, the benefits of the enthalpy heat recovery cell are available to the user even if the unit is not operating at the optimal level.

Later, when carrying out maintenance and ordering spare parts, it is important to note that the type code in the type plate is incorrect, because the heat recovery cell has been replaced.

Can a unit equipped with an enthalpy heat recovery cell be installed without a draining system for condensing water?

We do not recommend this. Enthalpy heat recovery cells have long been used in Central Europe, i.e. in climates that are much warmer than the Finnish climate. Therefore, an enthalpy heat recovery cell will cause some condensing in winter, albeit less than an aluminium heat recovery cell would. Thus, we always recommend providing the unit with drains.

Does the enthalpy heat recovery cell let odours or impurities in indoor air?

The enthalpy heat recovery cell is highly selective on water vapour. It facilitates the transfer of moisture from one air flow to another, but blocks odours and other impurities quite effectively.

Does the enthalpy heat recovery cell form moisture in dry indoor air?

No. An enthalpy heat recovery cell facilitates the transfer of already existing moisture from humid extract air to dry supply air. Indoor air humidity is attributable to doing laundry, cooking and breathing, for example. An empty apartment does not become humid on its own.

How much moisture does the cell recover?

The cell typically transfers approximately 50–70% of extract air moisture to supply air and vice versa.

Can I wash the enthalpy heat recovery cell?

Yes, you can. The cell can be washed with water and mild detergent. Be extremely careful when handling the cell to avoid damage to the cell layers.

Is there paper in the enthalpy heat recovery cell?

No. The cell is made from aluminium and a material called Metalpic, which combines aluminium and polymer.

What will happen if I change the cell type in the unit settings?

The cell type can only be changed in the unit’s expert settings, however, this does not affect the unit’s factory settings, which determine, for example, the defrost parameters for the unit’s original cell.

MyVallox 99 CFi RE12
HVAC number: 7912311
Product weight: 62.3 kg
Package weight: 65.1 kg
GTIN: 6438326007696
MyVallox 99 CFi LE12
HVAC number: 7912312
Product weight: 62.3 kg
Package weight: 65.1 kg
GTIN: 6438326007702