Vallox > Vallox 096 MC
Vallox 096 MC
Maximum recommended living area
139 m²
Annual efficiency (%)
77
Temperature efficiency of heat recovery (%)
85.7
SEC average climate
-32.412 kWh/m²a
Reference airflow rate
0.059 m³/s
Specific power input (SPI)
0.37 W/(m³/h)
Specific Fan Power (SFP)
1.332 kW/(m³/s)
Maximum extract airflow @ 100 Pa
88 l/s
Maximum supply airflow @ 100 Pa
84 l/s
Maximum supply airflow EcoDesign
302 m³/h
Duct outlets pcs
4
Duct outlet mm
125 mm
Product depth mm
428
Product width mm
600
Product height mm
545
Mounting place
Wall
Remote monitoring options
External voltage message 0-10 VDC
Bus control
None
Extract air fan power consumption
0.119 kW
Supply air fan power consumption
0.119 kW
Sound power level
48 dB
Cell type
Cross-counter flow cell
Cell
Aluminium
HRU cell bypass
Automatic heat recovery bypass
Defrosting method
Vallox on-demand -defrosting automatics with heat recovery cell bypass
Post-heating
Electrical resistor, 900 W
Encapsulation class
IP34