Vallox 101 MV

Vallox 101 MV

Production ends on 31.10.2023
Designed for low-ceiling premises, Vallox 101 MV is a quiet ventilation unit suitable for middle-sized apartments. Thanks to its low-structure frame, it can be easily placed on top of a washing tower in the bathroom, for instance. The integrated humidity and carbon dioxide sensors and the optional VOC sensor ensure energy-efficient operation of the ventilation unit by automating the ventilation as necessary. The supply air temperature always remains at the desired level, thanks to the heat recovery and the partial bypassing of it. The annual efficiency of Vallox 101 MV is 75%.

The ventilation unit may be registered with the free MyVallox Cloud service, which allows remote control of the unit. The cloud service also automatically updates the unit. The ventilation unit may also be controlled with a control panel or cooker hood. Vallox 101 MV can be connected to house automation via the Modbus RTU or KNX bus.

Read also about the new Vallox 99 ventilation unit.
Including accessories: Condensing water seal Vallox SilentKlick, wall mounting plate.

Category:
  • Maximum recommended living area 143 m²
  • Maximum extract airflow @ 100 Pa 98 l/s
  • Maximum supply airflow @ 100 Pa 90 l/s
  • Maximum supply airflow EcoDesign 331 m³/h
Suitable for the following applications
Apartment houses icon
Apartment houses
Small houses icon
Small houses
Maximum recommended living area 143 m²
Temperature efficiency of heat recovery (%) 81.5
SEC average climate -39.881 kWh/m²a
Reference airflow rate 0.063 m³/s
Specific power input (SPI) 0.366 W/(m³/h)
Specific Fan Power (SFP) 1.318 kW/(m³/s)
Maximum extract airflow @ 100 Pa 98 l/s
Maximum supply airflow @ 100 Pa 90 l/s
Maximum supply airflow EcoDesign 331 m³/h
Duct outlets pcs 4
Duct outlet mm 125 mm
Product depth mm 596
Product width mm 598
Product height mm 449
Product weight 60 kg
Package weight 62.2 kg
ETIM EF003701 electrical connection Connection cable with protective earthed plug
Mounting place Wall
Remote monitoring options MyVallox Cloud service, MyVallox Home network, External voltage message 0-10 VDC
Bus control Modbus RTU (standard feature), KNX converter (optional)
Extract air fan power consumption 0.115 kW
Supply air fan power consumption 0.115 kW
Sound power level 49 dB
Cell type Cross-counter flow cell
Cell Aluminium
HRU cell bypass Automatic heat recovery bypass, partial bypass with cool recovery
Defrosting method Vallox on-demand -defrosting automatics with heat recovery cell bypass
Post-heating Electrical resistor, 1500 W
Electrical connection 230 V / 50 Hz / 8,3 A
Unit maximum power consumption 1.75 kW