MyVallox 119 CFi enthalpy

MyVallox 119 CFi enthalpy

Coming to sales in spring 2025
The new MyVallox 119 CFi enthalpic ventilation unit is equipped with constant flow fans, which compensate for pressure differences and balance ventilation, keeping the air flow always at the preferred level in windy conditions, in tall buildings and during defrosting, regardless of the heat recovery bypass status. The constant flow feature compensates for separate exhaust fans and is extremely quiet.

The unit has an enthalpic cell that recovers both heat and moisture from extract air and transfers them to supply air. The unit keeps indoor air at a comfortable temperature and moisture level without a cold draught of air.

The new constant flow feature also makes the installer’s job easier as the air flow control is litre-based, and it can be adjusted directly through the control system. The unit can be commissioned by connecting it to a computer with an Ethernet cable.

The MyVallox 119 CFi models have an innovative two-handed frame. The unit has a door on both sides, and the handedness can be changed just by switching the positions of the doors. In other words, the handedness of the unit does not need to be decided when ordering the unit. The factory standard is R-handedness. The unit’s front door has separate filter doors. This means that changing the filters is effortless, without the need to open the whole unit.

The MyVallox 119 CFi enthalpic ventilation unit’s SEC class is A+.
Including accessories: Condensing water seal Vallox SilentKlick, wall mounting plate.

Category:
  • Maximum recommended living area 190 m²
  • Maximum extract airflow @ 100 Pa 117 l/s
  • Maximum supply airflow @ 100 Pa 116 l/s
  • Maximum supply airflow EcoDesign 416 m³/h
Suitable for the following applications
Small houses icon
Small houses
Maximum recommended living area 190 m²
Temperature efficiency of heat recovery (%) 88
SEC average climate -42.934 kWh/m²a
Reference airflow rate 0.081 m³/s
Specific power input (SPI) 0.237 W/(m³/h)
Specific Fan Power (SFP) 0.853 kW/(m³/s)
Maximum extract airflow @ 100 Pa 117 l/s
Maximum supply airflow @ 100 Pa 116 l/s
Maximum supply airflow EcoDesign 416 m³/h
Duct outlets pcs 4
Duct outlet mm 160 mm
Product depth mm 550
Product width mm 643
Product height mm 932
Product weight 64.8 kg
Package weight 72 kg
ETIM EF003701 electrical connection Connection cable with protective earthed plug
Mounting place Wall
Remote monitoring options MyVallox Cloud service, MyVallox Home network, External voltage message 0-10 VDC
Bus control KNX converter (optional), Modbus RTU (standard feature)
Extract air fan power consumption 0.24 kW
Supply air fan power consumption 0.24 kW
Sound power level 42 dB
Cell type Cross-counter flow cell
Cell Enthalpy
HRU cell bypass Automatic heat recovery bypass, partial bypass with cool recovery
Defrosting method Vallox on-demand -defrosting automatics with heat recovery cell bypass
Post-heating Electrical resistor, 900 W
Additional heating Electrical resistor, 1500 W
Electrical connection 230 V / 50 Hz / 12,2 A
Encapsulation class IP34
Unit maximum power consumption 2.6 kW
MyVallox 119 CFi XE02
SKU: 4122611
Product weight: 64.8 kg
Package weight: 72 kg
GTIN: 6438326001458