{"id":3781,"date":"2016-02-08T09:10:00","date_gmt":"2016-02-08T07:10:00","guid":{"rendered":"https:\/\/vallox.com\/kayttoasteeseen-perustuva-ilmanvaihto-tyopaikalla\/"},"modified":"2026-08-30T17:36:02","modified_gmt":"2026-08-30T14:36:02","slug":"ventilation-based-on-utilisation-at-work","status":"publish","type":"post","link":"https:\/\/www.vallox.com\/en\/ventilation-based-on-utilisation-at-work\/","title":{"rendered":"Ventilation based on utilisation at work"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Updated on 20.8.2026<\/p>\n\n\n\n<div style=\"height:70px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n    <div id=\"Section\" class=\"Block Section overflow-hidden w-full\">\n        <div class=\"Section-content relative max-w-[1088px] mx-auto w-full\">\n            \n<div  class=\"Image w-full h-auto mb-8\">\n    <img decoding=\"async\"\n        srcset=\"\n            https:\/\/www.vallox.com\/app\/uploads\/2023\/09\/TarpeenmukainenIlmanvaihtoTyopaikalla_1920x540px-1024x288.jpg 1024w,\n            https:\/\/www.vallox.com\/app\/uploads\/2023\/09\/TarpeenmukainenIlmanvaihtoTyopaikalla_1920x540px-768x216.jpg 768w,\n            https:\/\/www.vallox.com\/app\/uploads\/2023\/09\/TarpeenmukainenIlmanvaihtoTyopaikalla_1920x540px-300x84.jpg 300w,\n            https:\/\/www.vallox.com\/app\/uploads\/2023\/09\/TarpeenmukainenIlmanvaihtoTyopaikalla_1920x540px-150x150.jpg 150w,\n        \"\n        alt=\"\"\n        src=\"https:\/\/www.vallox.com\/app\/uploads\/2023\/09\/TarpeenmukainenIlmanvaihtoTyopaikalla_1920x540px-300x84.jpg\"\n        class=\"object-cover w-full h-auto\"\n    \/>\n    <\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>The greatest energy savings in ventilation is often gained with demand-controlled operation.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The energy consumed by ventilation falls down to less than half when the power of ventilation is reduced by the same amount. When the rooms are empty, the need for ventilation decreases significantly and it is sensible to decrease ventilation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Changing working environment &#8211; changing needs<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The length of a working day used to be standard. Everybody was at work from eight to four and the need was at its greatest then. Nowadays, however, the rooms are more varied and work is more mobile. Offices may be empty for long periods of time as the employees work remotely, visit their customers or sit at meetings. The quality of air in a meeting room full of people can be lousy, whereas ventilation is at full power in the offices, consuming energy unnecessarily.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Decentralised ventilation and carbon dioxide sensors create automatic room-specific ventilation. The sensors measure the quality of indoor air and boost ventilation when needed. This ensures that air in the meeting room stays fresh and the participants stay awake, while ventilation in the empty rooms decreases, keeping energy consumption in control.<\/p>\n\n\n    <\/div>\n<\/div>\n\n\n<section class=\"bg-[rgba(165,185,196,0.3)]\" >\n    <div class=\"FiftyFifty\n\n        relative\n        flex\n        justify-between\n        flex-col-reverse lg:flex-row-reverse\n    \">\n        <div class=\"w-full lg:w-1\/2 p-4 sm:p-8 md:p-12 lg:p-28 xl:p-32 sm:!px-8\">\n                            <h2 class=\"Title\n                    flex flex-col justify-start\n                    text-black\n                    text-lg sm:text-2xl md:text-xl xl:text-2xl 2xl:text-3xl\n                    font-bold leading-6 xl:leading-7\n                    mb-4\n                \">\n                    Occupancy-Based Ventilation in Workplaces\n                <\/h2>\n                                        <div class=\"flex flex-col justify-center\">\n                                            <span class=\"Text text-custom-gray-dark pb-2\">\n                            <p>The ventilation requirements of commercial buildings vary continuously according to how the spaces are used. Vallox Pureo air handling units provide a flexible solution by enabling ventilation to be controlled based on actual demand, in other words according to occupancy levels. Vallox Pureo air handling units are designed for a wide range of commercial applications, including offices, retail premises, industrial and warehouse buildings, as well as public facilities such as schools and daycare centres. In these types of buildings, ventilation requirements can vary significantly depending on occupancy, highlighting the importance of demand-based control.<\/p>\n\n                        <\/span>\n                                                        <\/div>\n                    <\/div>\n\n                    <div class=\"\n                self-stretch justify-self-stretch\n                w-full lg:w-1\/2\n                relative flex justify-center\n                lg:justify-start\n             \">\n                <img decoding=\"async\"\n                loading=\"lazy\"\n                class=\"object-cover h-full w-full\"\n                                    srcset=\"\n                        https:\/\/www.vallox.com\/app\/uploads\/2024\/09\/ValloxPureoTX_450x450px-150x150.webp 150w,\n                        https:\/\/www.vallox.com\/app\/uploads\/2024\/09\/ValloxPureoTX_450x450px-300x300.webp 300w,\n                        https:\/\/www.vallox.com\/app\/uploads\/2024\/09\/ValloxPureoTX_450x450px.webp 450w,\n                        https:\/\/www.vallox.com\/app\/uploads\/2024\/09\/ValloxPureoTX_450x450px.webp 450w,\n                        https:\/\/www.vallox.com\/app\/uploads\/2024\/09\/ValloxPureoTX_450x450px.webp 450w,\n                    \"\n                                src=\"https:\/\/www.vallox.com\/app\/uploads\/2024\/09\/ValloxPureoTX_450x450px.webp\"\n                alt=\"Vallox Pureo TX -tuotesarja\"\n                \/>\n            <\/div>\n            <\/div>\n<\/section>\n\n\n\n<div style=\"height:63px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Occupancy-Based Control with Pureo Air Handling Units in Commercial Buildings<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A key strength of Pureo air handling units is their versatile control capabilities. The units can be equipped with advanced control systems and integrated with the building automation system.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ventilation control can be implemented using:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Weekly schedules based on building occupancy hours<\/li>\n\n\n\n<li>Presence detectors<\/li>\n\n\n\n<li>Sensors such as CO\u2082, humidity, and VOC sensors<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">These enable the ventilation system to automatically adapt to occupancy levels and indoor air quality conditions. For example, a humidity sensor connected to a Pureo unit can detect increasing moisture loads in the indoor air and automatically boost ventilation when needed. Read more about this in the <a href=\"https:\/\/www.vallox.com\/en\/reference\/hygieniska-faciliteter-och-inomhusluft-for-brandman\/\" type=\"link\" id=\"https:\/\/www.vallox.com\/en\/reference\/hygieniska-faciliteter-och-inomhusluft-for-brandman\/\">reference<\/a> project of a fire station, where indoor air quality and ventilation performance were improved with a Vallox Pureo TX air handling unit.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">An Energy-Efficient and Easily Adaptable Pureo System<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Pureo air handling units can be delivered either as terminal block units without controls or with a complete control system including electrical and control equipment. Automation can also be expanded later by adding sensors, making it possible to upgrade the system to demand-controlled, occupancy-based ventilation as requirements evolve. In addition, the units are compatible with various building automation systems, enabling ventilation to be integrated into broader building management solutions.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The energy efficiency of Vallox Pureo air handling units is enhanced by highly efficient heat recovery, which improves the overall energy performance of the ventilation system.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">When ventilation adapts to occupancy levels, unnecessary ventilation is reduced, energy consumption decreases, and indoor environmental conditions remain well controlled. Demand-controlled operation complements the benefits of heat recovery by ensuring that the right amount of ventilation is provided at the right time. As a result, ventilation can be delivered efficiently, energy-efficiently, and in line with the actual usage of a wide range of commercial buildings.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Updated on 20.8.2026 Occupancy-Based Control with Pureo Air Handling Units in Commercial Buildings A key strength of Pureo air handling units is their versatile control capabilities. The units can be equipped with advanced control systems and integrated with the building automation system. Ventilation control can be implemented using: These enable the ventilation system to automatically [&hellip;]<\/p>\n","protected":false},"author":5,"featured_media":4275,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[236],"tags":[237],"class_list":["post-3781","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-artikkelit-en","tag-yleinen-en"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Ventilation based on utilisation at work - Vallox<\/title>\n<meta name=\"description\" content=\"The greatest energy savings in ventilation are often gained with demand-controlled operation.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.vallox.com\/en\/ventilation-based-on-utilisation-at-work\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Ventilation based on utilisation at work - Vallox\" \/>\n<meta property=\"og:description\" content=\"The greatest energy savings in ventilation are often gained with demand-controlled operation.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.vallox.com\/en\/ventilation-based-on-utilisation-at-work\/\" \/>\n<meta property=\"og:site_name\" content=\"Vallox\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/valloxoy\" \/>\n<meta property=\"article:published_time\" content=\"2016-02-08T07:10:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-30T14:36:02+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.vallox.com\/app\/uploads\/2023\/06\/Artikkeli_TyopaikanIlmanvaihto_listauskuva_940x628px.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"940\" \/>\n\t<meta property=\"og:image:height\" content=\"628\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Viola Juuso\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Viola Juuso\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.vallox.com\\\/en\\\/ventilation-based-on-utilisation-at-work\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.vallox.com\\\/en\\\/ventilation-based-on-utilisation-at-work\\\/\"},\"author\":{\"name\":\"Viola Juuso\",\"@id\":\"https:\\\/\\\/www.vallox.com\\\/en\\\/#\\\/schema\\\/person\\\/f044541c8c8daf7c7be6749fb9ed43fb\"},\"headline\":\"Ventilation based on utilisation at work\",\"datePublished\":\"2016-02-08T07:10:00+00:00\",\"dateModified\":\"2026-08-30T14:36:02+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.vallox.com\\\/en\\\/ventilation-based-on-utilisation-at-work\\\/\"},\"wordCount\":500,\"publisher\":{\"@id\":\"https:\\\/\\\/www.vallox.com\\\/en\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.vallox.com\\\/en\\\/ventilation-based-on-utilisation-at-work\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.vallox.com\\\/app\\\/uploads\\\/2023\\\/06\\\/Artikkeli_TyopaikanIlmanvaihto_listauskuva_940x628px.jpg\",\"keywords\":[\"yleinen\"],\"articleSection\":[\"Articles\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.vallox.com\\\/en\\\/ventilation-based-on-utilisation-at-work\\\/\",\"url\":\"https:\\\/\\\/www.vallox.com\\\/en\\\/ventilation-based-on-utilisation-at-work\\\/\",\"name\":\"Ventilation based on utilisation at work - Vallox\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.vallox.com\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.vallox.com\\\/en\\\/ventilation-based-on-utilisation-at-work\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.vallox.com\\\/en\\\/ventilation-based-on-utilisation-at-work\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.vallox.com\\\/app\\\/uploads\\\/2023\\\/06\\\/Artikkeli_TyopaikanIlmanvaihto_listauskuva_940x628px.jpg\",\"datePublished\":\"2016-02-08T07:10:00+00:00\",\"dateModified\":\"2026-08-30T14:36:02+00:00\",\"description\":\"The greatest energy savings in ventilation are often gained with demand-controlled operation.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.vallox.com\\\/en\\\/ventilation-based-on-utilisation-at-work\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.vallox.com\\\/en\\\/ventilation-based-on-utilisation-at-work\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.vallox.com\\\/en\\\/ventilation-based-on-utilisation-at-work\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.vallox.com\\\/app\\\/uploads\\\/2023\\\/06\\\/Artikkeli_TyopaikanIlmanvaihto_listauskuva_940x628px.jpg\",\"contentUrl\":\"https:\\\/\\\/www.vallox.com\\\/app\\\/uploads\\\/2023\\\/06\\\/Artikkeli_TyopaikanIlmanvaihto_listauskuva_940x628px.jpg\",\"width\":940,\"height\":628,\"caption\":\"ty\u00f6paikanilmanvaihto_n\u00e4pp\u00e4imist\u00f6jahiiri\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.vallox.com\\\/en\\\/ventilation-based-on-utilisation-at-work\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.vallox.com\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Ventilation based on utilisation at work\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.vallox.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.vallox.com\\\/en\\\/\",\"name\":\"Vallox\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.vallox.com\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.vallox.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.vallox.com\\\/en\\\/#organization\",\"name\":\"Vallox Oy\",\"alternateName\":\"Vallox\",\"url\":\"https:\\\/\\\/www.vallox.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.vallox.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.vallox.com\\\/app\\\/uploads\\\/2026\\\/02\\\/ValloxLogo-HomeSlogan_RGB_Main_500px.webp\",\"contentUrl\":\"https:\\\/\\\/www.vallox.com\\\/app\\\/uploads\\\/2026\\\/02\\\/ValloxLogo-HomeSlogan_RGB_Main_500px.webp\",\"width\":500,\"height\":262,\"caption\":\"Vallox Oy\"},\"image\":{\"@id\":\"https:\\\/\\\/www.vallox.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/valloxoy\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/vallox-oy\\\/\",\"https:\\\/\\\/www.instagram.com\\\/valloxoy\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.vallox.com\\\/en\\\/#\\\/schema\\\/person\\\/f044541c8c8daf7c7be6749fb9ed43fb\",\"name\":\"Viola Juuso\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/66a06262981bfaee600d4fc405a92c846ae081d555b32e08ee7b8b43fe1fc3ba?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/66a06262981bfaee600d4fc405a92c846ae081d555b32e08ee7b8b43fe1fc3ba?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/66a06262981bfaee600d4fc405a92c846ae081d555b32e08ee7b8b43fe1fc3ba?s=96&d=mm&r=g\",\"caption\":\"Viola Juuso\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Ventilation based on utilisation at work - Vallox","description":"The greatest energy savings in ventilation are often gained with demand-controlled operation.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.vallox.com\/en\/ventilation-based-on-utilisation-at-work\/","og_locale":"en_US","og_type":"article","og_title":"Ventilation based on utilisation at work - Vallox","og_description":"The greatest energy savings in ventilation are often gained with demand-controlled operation.","og_url":"https:\/\/www.vallox.com\/en\/ventilation-based-on-utilisation-at-work\/","og_site_name":"Vallox","article_publisher":"https:\/\/www.facebook.com\/valloxoy","article_published_time":"2016-02-08T07:10:00+00:00","article_modified_time":"2026-08-30T14:36:02+00:00","og_image":[{"width":940,"height":628,"url":"https:\/\/www.vallox.com\/app\/uploads\/2023\/06\/Artikkeli_TyopaikanIlmanvaihto_listauskuva_940x628px.jpg","type":"image\/jpeg"}],"author":"Viola Juuso","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Viola Juuso","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.vallox.com\/en\/ventilation-based-on-utilisation-at-work\/#article","isPartOf":{"@id":"https:\/\/www.vallox.com\/en\/ventilation-based-on-utilisation-at-work\/"},"author":{"name":"Viola Juuso","@id":"https:\/\/www.vallox.com\/en\/#\/schema\/person\/f044541c8c8daf7c7be6749fb9ed43fb"},"headline":"Ventilation based on utilisation at work","datePublished":"2016-02-08T07:10:00+00:00","dateModified":"2026-08-30T14:36:02+00:00","mainEntityOfPage":{"@id":"https:\/\/www.vallox.com\/en\/ventilation-based-on-utilisation-at-work\/"},"wordCount":500,"publisher":{"@id":"https:\/\/www.vallox.com\/en\/#organization"},"image":{"@id":"https:\/\/www.vallox.com\/en\/ventilation-based-on-utilisation-at-work\/#primaryimage"},"thumbnailUrl":"https:\/\/www.vallox.com\/app\/uploads\/2023\/06\/Artikkeli_TyopaikanIlmanvaihto_listauskuva_940x628px.jpg","keywords":["yleinen"],"articleSection":["Articles"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.vallox.com\/en\/ventilation-based-on-utilisation-at-work\/","url":"https:\/\/www.vallox.com\/en\/ventilation-based-on-utilisation-at-work\/","name":"Ventilation based on utilisation at work - Vallox","isPartOf":{"@id":"https:\/\/www.vallox.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.vallox.com\/en\/ventilation-based-on-utilisation-at-work\/#primaryimage"},"image":{"@id":"https:\/\/www.vallox.com\/en\/ventilation-based-on-utilisation-at-work\/#primaryimage"},"thumbnailUrl":"https:\/\/www.vallox.com\/app\/uploads\/2023\/06\/Artikkeli_TyopaikanIlmanvaihto_listauskuva_940x628px.jpg","datePublished":"2016-02-08T07:10:00+00:00","dateModified":"2026-08-30T14:36:02+00:00","description":"The greatest energy savings in ventilation are often gained with demand-controlled operation.","breadcrumb":{"@id":"https:\/\/www.vallox.com\/en\/ventilation-based-on-utilisation-at-work\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.vallox.com\/en\/ventilation-based-on-utilisation-at-work\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.vallox.com\/en\/ventilation-based-on-utilisation-at-work\/#primaryimage","url":"https:\/\/www.vallox.com\/app\/uploads\/2023\/06\/Artikkeli_TyopaikanIlmanvaihto_listauskuva_940x628px.jpg","contentUrl":"https:\/\/www.vallox.com\/app\/uploads\/2023\/06\/Artikkeli_TyopaikanIlmanvaihto_listauskuva_940x628px.jpg","width":940,"height":628,"caption":"ty\u00f6paikanilmanvaihto_n\u00e4pp\u00e4imist\u00f6jahiiri"},{"@type":"BreadcrumbList","@id":"https:\/\/www.vallox.com\/en\/ventilation-based-on-utilisation-at-work\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.vallox.com\/en\/"},{"@type":"ListItem","position":2,"name":"Ventilation based on utilisation at work"}]},{"@type":"WebSite","@id":"https:\/\/www.vallox.com\/en\/#website","url":"https:\/\/www.vallox.com\/en\/","name":"Vallox","description":"","publisher":{"@id":"https:\/\/www.vallox.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.vallox.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.vallox.com\/en\/#organization","name":"Vallox Oy","alternateName":"Vallox","url":"https:\/\/www.vallox.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.vallox.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.vallox.com\/app\/uploads\/2026\/02\/ValloxLogo-HomeSlogan_RGB_Main_500px.webp","contentUrl":"https:\/\/www.vallox.com\/app\/uploads\/2026\/02\/ValloxLogo-HomeSlogan_RGB_Main_500px.webp","width":500,"height":262,"caption":"Vallox Oy"},"image":{"@id":"https:\/\/www.vallox.com\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/valloxoy","https:\/\/www.linkedin.com\/company\/vallox-oy\/","https:\/\/www.instagram.com\/valloxoy\/"]},{"@type":"Person","@id":"https:\/\/www.vallox.com\/en\/#\/schema\/person\/f044541c8c8daf7c7be6749fb9ed43fb","name":"Viola Juuso","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/66a06262981bfaee600d4fc405a92c846ae081d555b32e08ee7b8b43fe1fc3ba?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/66a06262981bfaee600d4fc405a92c846ae081d555b32e08ee7b8b43fe1fc3ba?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/66a06262981bfaee600d4fc405a92c846ae081d555b32e08ee7b8b43fe1fc3ba?s=96&d=mm&r=g","caption":"Viola Juuso"}}]}},"_links":{"self":[{"href":"https:\/\/www.vallox.com\/en\/wp-json\/wp\/v2\/posts\/3781","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.vallox.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.vallox.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.vallox.com\/en\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/www.vallox.com\/en\/wp-json\/wp\/v2\/comments?post=3781"}],"version-history":[{"count":9,"href":"https:\/\/www.vallox.com\/en\/wp-json\/wp\/v2\/posts\/3781\/revisions"}],"predecessor-version":[{"id":32137,"href":"https:\/\/www.vallox.com\/en\/wp-json\/wp\/v2\/posts\/3781\/revisions\/32137"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.vallox.com\/en\/wp-json\/wp\/v2\/media\/4275"}],"wp:attachment":[{"href":"https:\/\/www.vallox.com\/en\/wp-json\/wp\/v2\/media?parent=3781"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.vallox.com\/en\/wp-json\/wp\/v2\/categories?post=3781"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.vallox.com\/en\/wp-json\/wp\/v2\/tags?post=3781"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}