Vallox 90 MV
Temperature efficiency of heat recovery (%)
83.4
SEC average climate
-39.825 kWh/m²a
Reference airflow rate
0.048 m³/s
Specific power input (SPI)
0.4 W/(m³/h)
Specific Fan Power (SFP)
1.44 kW/(m³/s)
Maximum extract airflow @ 100 Pa
85 l/s
Maximum supply airflow @ 100 Pa
70 l/s
Maximum supply airflow EcoDesign
252 m³/h
Duct outlets pcs
4
Duct outlet mm
125 mm
Product depth mm
361
Product width mm
597
Product height mm
689
ETIM EF003701 electrical connection
Connection cable with protective earthed plug
Mounting place
Wall
Remote monitoring options
MyVallox Cloud service, MyVallox Home network, External voltage message 0-10 VDC
Bus control
Modbus RTU (standard feature), KNX converter (optional)
Extract air fan power consumption
0.119 kW
Supply air fan power consumption
0.119 kW
Sound power level
42 dB
Cell type
Cross-counter flow cell
Cell
Aluminium
Vallox 90 MV LA11
HVAC number: 7912067
Digital adjustment. MyVallox control panel included in the price.
GTIN: 6415879120676
In production: No